Wednesday, September 27, 2017

When Band-Pass/Band-Reject (Bp/Br) duplexers really aren't band-pass

Addendum: 

Since this article was originally published, the availability of low-cost test equipment like the NanoVNA has allowed more-thorough testing of their RF signal paths.

With the advent of inexpensive and "good" test equipment like a NanoVNA, there is little excuse these days for not knowing if one's duplexer has the needed band-pass characteristics described in this article.

* * * * * *

In the repeater world there is a misconception that just because the duplexer may say "Band Pass, Band Reject" on its label - or even in its 'spec sheet - that it really does offer a proper band-pass response over a wide range of frequencies - but this is usually NOT the case.

A close-in look at a typical Band-Pass/Band-Reject duplexer:

Take Figure 1, below, as an example.

Figure 1:
The magenta trace is that of a proper band-pass cavity, the yellow trace is that of a one side (3 cavities) of a 6-cavity Phelps-Dodge "Band-Pass/Band-Reject" duplexer while the cyan trace is the combination of the two.  The top of the yellow peak (with the "1" marker) represents the center frequency of the duplexer with a bit over 1dB loss.

In the analyzer trace above, the YELLOW is the response of one of half of a typical amateur "Band-Pass/Band-Reject" 6-can Phelps-Dodge duplexer tuned in the 2-meter amateur band and from this trace we can see several things happening:
  • As there should be, there is a peak at the pass frequency corresponding to the "band-pass" of the duplexer - in this case, a bit over 1dB loss.
  • Just above the peak - 600 kHz, to be precise - is a very deep notch - corresponding to the frequency to "band-reject" part of the name.  In reality, the depth of the notch depicted in Figure 1 is about 100dB, but the true depth is not apparent from the trace.
  • Once one moves about 1 division (1.5 MHz) either side of the peak/notch frequency, the attenuation isn't that great - only about 20-30dB, and the trace above the center seems to be on a asymptotic trajectory upwards (lower attenuation) as frequency increases.
From the above we can see that while this duplexer offers a "Band-Pass/Band-Reject" response, this occurs only at frequencies very near the input/output frequencies of our hypothetical repeater.  Once you get "farther away", this "band-pass" response diminishes.

On the other hand the MAGENTA trace shows a single band-pass cavity filter.  While its attenuation is not very high at the notch frequency - on the order of 10-15dB - it is apparent that by 2 MHz above the center frequency it is offering greater attenuation than the so-called "Band-Pass/Band-Reject" filter and that below the center, the trend indicates that they might cross over at a point just to the left of the trace.

Comment:  This "Bp/Br" nomenclature is widely applied amongst many manufacturers to duplexers that have the same response as the Phelps-Dodge duplexer above, including Motorola and Wacom - to name but a few.  It is the rare exception to find a "Band-pass/Band-Reject" duplexer that does NOT exhibit the properties described on this page!

Unless you have already installed some band-pass cavities on each leg of your duplexer and/or have done proper sweep responses at frequencies far removed from the designed frequency, you should not assume that your "Bp/Br" duplexer is truly Band-Pass/Band-Reject over a very wide frequency range!

Taking a wider view:

Figure 1 only spans about 7.5 MHz on either side of 2 meters, so let us widen it a bit as shown in Figure 2, below:

Figure 2:
Spanning from 30 MHz to 1 GHz, the same cavities/filters as noted above.  Again, the yellow trace is one half of a 6-cavity "Band-Pass/Band-Reject" duplexer, the magenta trace is the pass cavity alone and the cyan trace is the result of the bandpass cavity and the Bp/Br duplexer cascaded.  It should be noted that at odd-numbered harmonics the pass cavity
will present a narrow bandpass response that can be eliminated with the addition of a simple low-pass filter.


When looking over a much wider frequency range - 30 MHz to 1 GHz - the picture is quite different.  Based on this sweep we can see that our typical "6 can" duplexer - of which 3 "cans" of the transmit or receive side - are represented above in YELLOW and that for the majority of the frequency range there is relatively little attenuation offered overall!  Paying particular attention we see that the attenuation in much of the VHF-low TV band (channels 2-6) and the FM broadcast band is quite poor - on the order of 3-10dB - as is the case over much of the VHF-high (channels 7-13) and large sections of the UHF TV band.

What we can see from this picture is that if we rely on only our so-called "band-pass/band-reject" duplexer on a site with other services such as FM or TV broadcast, or even land-mobile, those frequencies just above the amateur band, such a duplexer offers relatively little protection against those signals getting into the transmitter or receiver.

Why it matters:

One might wonder why it would matter whether or not a duplexer offered good "far-off-frequency" rejection.

In many cases, particularly in mountainous areas, amateur repeaters are co-located at sites with other transmitters and if adequate filtering is not implemented those "other" signals can get into the repeater's receiver and/or transmitter.

The effects of these other signals' ingress into the receiver is easier to envision:  Many of us have observed that, while driving about, our mobile radios have occasionally been overloaded with other signals - the effect being that we are hearing signals on frequencies where they are not.  This phenomenon is the inevitable result of the receiver's mixer - a device that is designed specifically to make new signals out of multiple signals in the first place - synthesizing entirely new ones out of the several that get in via its antenna.

Several decades ago it was common for land-mobile VHF and UHF radios to have receivers that had very tight filtering as there were typically only a few, closely-spaced channels that were used.  By virtue of this extensive filtering it was unlikely that other signals' somewhat-removed frequencies could even get in and cause undesired signals to be generated.  These days most radios have very broad filtering in their receiver inputs - this, to allow a wide range of frequencies to be accommodated.  While convenient, this also has a down side:  Those formerly widely-spaced frequencies from other services now have little impediment and it is more likely that they will get into the receiver and produce undesired, spurious signals.

Many years ago it was also the case that many repeaters used modified land-mobile radios with their extensive filtering, but nowadays many "store bought" repeaters (such as the Icom D-Star and Yaesu Fusion lines) are simply beefed-up mobile radios with "broad as the proverbial barn door" filtering on their receivers.  While this is convenient for the repeater owner to not have to dig up some test equipment and tune up these receivers' narrow filters, this also means is that there are many instances where a club has replaced their old, crystal-controlled analog repeater with a new one - only to find out that it did not work well at all when these off-frequency signals - formerly blocked by the old receiver's narrow front-end filter - clobbered the new receiver.  Worse still, some of these repeaters (namely the Icom D-Star) provided no analog test points where the receiver performance could be directly analyzed to determine if there was a problem, much less its extent!

What's worse is it is often the case that at many sites this sort of interference may be intermittent in nature - occurring only when a certain combination of transmitters happened to be online at once:  With most repeaters using subaudible tones for access, this degradation is often masked since the repeater may stay silent when it is being impacted, the only clue being that some users may suddenly find it difficult to get in to the repeater with a good signal at random times.  In other words, unless one uses the proper test equipment to take and record repeatable measurements at or away from the site, gradual or occasional degradation of the receiver's performance may not be so apparent.

An insidious problem:

While the overloading of a receiver is a familiar problem to many of us, it may not be as obvious that a similar thing can happen in a transmitter.  Like a receiver, a transmitter has the ability to take two signals and produce others via mixing.  For this to happen it usually requires that the "other" signals are very strong - but this is something that can happen at a busy radio site!

As a demonstration of what can happen, it was noted that via a VHF antenna atop Farnsworth Peak near Salt Lake City, Utah - a very busy broadcast site - one could read 100-150 milliwatts of RF on the coaxial cable at the input to the duplexer.  When this energy was analyzed it was found to be a combination of FM broadcast and UHF TV signals - the same transmitters that produce several megawatts of effective radiated power, combined.  If the same 6-cavity duplexer depicted in Figure 1 and Figure 2 was inserted in the line, this power would reduced - but only to the 20-50 milliwatt level!

This power was measured on the feedline of what would be a D-Star repeater, but prior to the installation of that repeater an analog Kenwood TK-740 repeater had been used for several months to assess coverage and performance prior to the installation of the Icom D-Star repeater.

On the day that the D-Star repeater was installed it was discovered that no-one could get into it, despite their running 50 watts.  Upon analysis it was discovered that the 20-50 milliwatts coming back into the coax was causing the Icom repeater's receiver to be deafened (desensed) by about 40dB - a factor of 10,000-fold!  Upon reconnecting the TK-740, no problems were noted and it was realized that the Kenwood repeater had a more traditional, narrow-band helical resonator filter assembly in its front end and compared to the more modern "broad-band" front end of the Icom repeater - which used parts of modified mobile radios - that the power in from the antenna was completely demolishing its receiver!


Figure 3:
A typical Motorola  4-can duplexer for UHF.  Just like its VHF counterparts
it easily passes energy at frequencies above and below its tuned frequency.
Click on the image for a larger version.

The installation of two bandpass cavities on the receive side allowed the Icom repeater to work as well as the old Kenwood analog repeater with its superior filtering - but this brings up the question about what might happen on transmit?

The transmitter can also act as a mixer:  Multiple signals - one of which might be the repeater's output frequency - can combine within the circuitry and instead of only the transmit frequency being emitted, some conglomeration of signals can appear!

In the example of a VHF transmitter we know that while the low-pass filter may remove the frequencies above the 2-meter band - say, UHF land-mobile and UHF TV - it will do nothing to remove energy from FM broadcast stations.  Similarly, if this were a UHF transmitter, its low-pass filter might remove some of the UHF land-mobile and UHF TV energy, but it would have little effect on signals from FM broadcast and VHF high and low band TV.

It might be suggested at this point that the use of an isolator - a device that, while allowing the transmitter's energy to go to the antenna, it directs any power coming back down the coax into a dummy load so that it cannot even get to the transmitter, might be appropriate here - and this would be correct...  Mostly.  While these devices are invaluable - and even required equipment at many radio sites - to both prevent RF from nearby-frequency transmitters from getting into your transmitter - and then re-radiated again and also to insulate your transmitter from a bad VSWR - it is far less-effective when the frequencies that are coming back down the coaxial cable are away from its design frequency.  In other words, while your VHF isolator may work okay from 140 to 160 MHz, it will probably do comparatively little at the FM broadcast band and in the UHF range.

Adding a pass cavity:

It is, therefore, a very good idea to equip any repeater with at least two pass cavities:  One on the receiver, tuned to the input frequency and another on the transmitter, after the isolator, tuned to the output frequency.

If one examines both Figures 1 and 2 you can see the Magenta trace showing the response of a single pass cavity.  When compared to the response of a typical Bp/Br duplexer (the YELLOW trace) the general trend is that the farther away one gets from the pass frequency, the more attenuation it offers.  One quirk of band-pass cavities is that they also have a response at odd multiples of their pass frequency, which means that a 2-meter pass cavity will also pass energy around the low end of 70cm, around 700 MHz, and so-on.  In the case of 2 meters, this spurious response could be eliminated by the addition of a low-pass filter.

Both figures 1 and 2 also show something else:  What happens if you cascade a Bp/Br duplexer with a single pass cavity (the CYAN trace)?  For the most part the overall attenuation of the two sets of filters is complementary - that is, the "best of both worlds."  As can be seen the simple addition of a pass cavity knocks out almost everything that is off-frequency from that which is desired.
Figure 4:
A typical "4 can" (2 on transmit, 2 on receive)
2-meter duplexer.  Even though it is labeled
as a "band-pass/band reject" unit, this refers only
to the two frequencies of interest - the transmit
and receive - and not to the RF spectrum overall!
The plots in Figures 1 and 2 are from a similar,
"6-can" (3 on tx, 3 on rx) duplexer, but the
rejection of frequencies "far removed" from
where they are tuned is comparable.
Click on the image for a larger version.

Bandpass cavities have another important property as well:  Lightning protection.  Because lightning is a broad-band energy spike, it would make sense that if you reduce the passband of the signal path from the antenna, less RF energy, overall, will get in - and the use of a passband cavity also guarantees that there is NO DC path from the center pin of the coax from the antenna to the center pin of the coax going to the radio.  One radio club - the Utah Amateur Radio Club - has several mountain top repeaters and there have been a number of instances where the repeater antenna has taken a direct lightning hit, sometimes destroying the antenna, but never has the attached receiver or transmitter ever been damaged.

Summation:

If you are installing a repeater or other radio at a site with any other transmitters you should not assume that just because the label or specifications of the duplexer say that it is "Band-Pass/Band-Reject" that it will actually do so over a wide range of frequencies.  Again, most brands of duplexers will simply pass, with relatively little attenuation, those frequencies that are far removed from the operating frequencies and the "band-pass/band-reject" nature is limited to the specific frequencies of interest - such as the transmit side of the duplexer passing the transmit signal but rejecting energy at the receive frequency.

Such a duplexer should always be supplemented with at least one bandpass cavity for the transmit frequency and another for the receive frequency to provide additional off-frequency rejection - and adding a simple low-pass filter on each leg won't hurt, either.  While these added elements result in higher signal loss, this need only be 1dB or less in most cases.  Adding this extra cavity will increase the effectiveness of an isolator on the transmitter - which works only well near its design frequency anyway - but it will also prevent excess, off-frequency energy from getting into the repeater's receiver which, these days, is more typically a "mobile" unit with a very broad front end that has been converted.  Finally, the humble band-pass cavity provides good lightning protection, just by its very nature!

[End]

This page stolen from ka7oei.blogspot.com



Dh9TC1lk6V11s57h0977

Tuesday, September 12, 2017

Using an inexpensive MPPT controller in a portable solar charging system

As I'm wont to do, I occasionally go backpacking, carrying (a bit too much!) gear with me - some of it being electronic such as a camera, GPS receiver and ham radio(s).  Because I'm usually out for a week or so - and also because I often have others with me that may also have battery-powered gear, there arises the need for a way to keep others' batteries charged as well.

Having done this for decades I've carried different panels with me over that time, wearing some of them out in the process, so it was time for a "refresh" and a new system using both more-current technology and based, in part, on past lessons learned.

Why 12 volt panels?

If you look about you'll find that there are a lot of panels nowadays that are designed to charge USB devices -which is fine if all you need to do is charge USB devices, but many cameras, GPS receivers, radios and other things aren't necessarily compatible with being charged from just 5 volts.  The better solution in these cases is to start out with a higher voltage - say that from a "12 volt" panel intended for also keeping a car battery afloat - and convert it down to the desired voltage(s) as needed.

After a bit of difficulty in finding a small, lightweight panel that natively produced the raw "12 volts" output from the array (actually, 16-22 volts unloaded) I found a 18 watt folding panel that weighed just a bit more than a pound by itself.  It happened to also include a USB charge socket - but can be hard to find one without that accessory!
Figure 1:
The 6-7aH LiFePO4 battery, MPPT controller and "18 watt" solar panel.
The odd shape of the LiFePO4 battery is due to its being intended to power
bicycle lighting, fitting in a water bottle holder.
Click on the image for a larger version.

By operating at "12 volts" you now have the choice of practically any charging device that can be plugged into a car's 12 volt accessory socket (e.g. cigarette lighter) and there are plenty of those about for nearly anything from AA/AAA chargers for things like GPS receivers and flashlights to those designed to charge your camera.  An advantage of these devices is that nowadays, they are typically very small and lightweight, using switching power converters to take the panels voltage down to what is needed with relatively little loss.

But there is a problem.

If you use a switching power converter to take a high voltage down to a lower voltage, it will dutifully try to maintain a constant power output - which means that it will also attempt to maintain a constant power input as well - and this can lead to a vexing problem.


Take as an example of a switching power converter that is 100% efficient, charging a 5 volt device at 2 amps, or (5 volts * 2 amps =) 10 watts.

If we are feeding this power converter with 15 volts, we need (10 watts / 15 volts =) 0.66 amps, but if we are supplying it with just 10 volts, we will need (10 watts / 10 volts =) 1 amp - all the way down to 2 amps at 5 volts.  What this means is that while we always have 10 watts with these differing voltages, we will need more current as the voltage from the panel goes down.

Now suppose that we have a 15 watt solar panel.  As is the nature of solar panels, there is a "magic" voltage at which our wattage (volts * amps) will be maximum, but there is also a maximum current that a panel will produce that remains more or less constant, regardless of the voltage.  What this means is that if our panel can produce its maximum power at 15 volts where it is producing 1 amps, if we overload the panel slightly and cause its voltage to go down to, say, 10 volts, it will still be producing about 1 amp - but only making (10 volts * 1 amp =) 10 watts of power!  Clearly, if we wish to extract maximum power to make the most of daylight we will want to pick the voltage at which we can get the maximum power.

Dealing with "stupid" power converters:

Suppose that, in our example, we are happily producing 10 watts of power to charge that 5 volt battery at 2 amps.  At 15 volts, we need only 0.66 amps to get that 10 watts, but then a black cloud comes over and the panel can now produce only 0.25 amps.  Because our switching converter is "stupid", it will always try to pull 10 watts - but when it does so, the voltage on its input, from the panel, will drop.  In this scenario, our voltage converter will pull the voltage all of the way down to about 5 volts - but since the panel can only produce 0.25 amps, we will be charging with only (5 volts * 0.25 amps =) 1.25 watts.


Now, the sun comes out - but the switching converter, being stupid, is still trying to pull 10 watts, but since it has pulled the voltage down to 5 volts to charge the battery, we will need 2 amps to feed the converter the 10 watts that it will need to be happy, but since our panel can never produce more than an amp, it will be stuck there, forever, producing about only (5 volts * 1 amp =) 5 watts.

If we were to disconnect the battery being charged momentarily so that the switching converter no longer saw its load and needed to try to output 10 watts, the input voltage would go back up to 15 volts - and then when we reconnected the battery, it would happily pull 0.66 amps at 15 volts again and resume charging the battery at 10 watts - but it will never "reset" itself on its own.

What this means is that you should NEVER connect a standard switching voltage converter directly to a solar panel or it will get "stuck" at a lower voltage and power if the available panel output drops below the required load - even for a moment!

Work-arounds to this "stuck regulator" problem:


The Linear regulator

One obvious work-around to this problem where a switching regulator gets "stuck" is to simply avoid using them, instead using an old-fashioned linear regulator such as an LM317 variable regulator or a fixed-voltage regulator in the 78xx series (e.g. 7805 for our 5 volt example).  This type of regulator, if outputting 1 amp, will also require an input of 1 amp, the difference in voltage being lost as heat.  If a black cloud comes over - or it is simply morning/evening with less light - and the panel outputs less current, that lower current will simply be passed along to the load.

The problem with a linear regulator is that it can be very inefficient, particularly if the voltage is being dropped significantly.  For example, if you were to charge the 5 volt device at 1 amp from a panel producing 15 volts, your panel would be producing (15 volts * 1 amp =) 15 watts, you would be charging your device at (5 volts * 1 amp =) 5 watts, but your linear regulator would be burning up the difference -10 watts of heat - wasting most of the energy.  On the up side, it simply cannot get "stuck" like a switching converter, it is very simple, it will cause no radio interference, and it is nearly foolproof in its operation.

Figure 2:
The front of the EvilBay "5 amp MPPT charger".  This unit is
an inexpensive unit that used the "Constant Voltage" algorithm (see
below) and designed primarily to charge lithium chemistry batteries.
One of the potentiometers is used to set the final charge voltage - between
14.2 and 14.6 volts for a "4 cell" LiFePO4 - and the other is set to the "maximum
power voltage" of the panels to which it is connected.  This unit- as do most
inexpensive units -require that the MPPT voltage of the panels be 2-3 volts
higher than the final charge voltage of the battery being charged.
Click on the image for a larger version.

MPPT power controller

A better solution in terms of power utilization would be to use a more intelligent device such as an MPPT (Maximum Power Point Tracking) regulator.  This is a "smarter" version of the switching regulator that, by design, avoids getting "stuck" by tracking how much power is actually available from the solar panel and never tries to pull more current than is available.  For this discussion we'll talk about the two most common types of MPPT systems.

"Perturb and Observe" MPPT:

This method monitors both the current and voltage being delivered by the panel and internally, calculates the wattage (e.g. volts * amps) on the fly and under normal conditions, and it will change the amount of current that it is trying to pull from the panel up and down slightly to see what happens, hence the name "Perturb and Observe" (a.k.a. "P&O").

For example, suppose that our goal is to get the maximum amount of power and our panel is producing 15 volts at 1 amp, or 15 watts.  Now, the MPPT controller will try to pull, say, 1.1 amps from the panel.  If the panel voltage drops slightly to 14.5 volts so we are now supplying (1.1 amps * 14.5 volts =) 15.95 watts and we were successful in pulling more power to be delivered to our load.  Now, it will try again, this time to pull 1.2 amps from the panel, but it finds that when it does so the panel voltage drops to 12.5 volts and we are now getting (1.2 amps * 12.5 volts =) 15 watts - clearly a decrease!  Realizing its "mistake" it will quickly go back to pulling 1.1 amps to get back to the setting where it can pull more power.  After this it may reduce its current to 1 amp again to "see" if things have changed and whether or not we can get more power - or if, perhaps, the amount of sunlight has dropped - such that trying to pull less current is the optimal setting.

By constantly "trying" different current combinations to see what provides the most power it will be able to track the different conditions that can affect power output of the solar panel - namely the amount of sun hitting it, the angle of that sun and to a lesser extent, the temperature of the solar panel.

Figure 3:
Curves showing the voltage versus current of a typical solar cell.  Once
the current goes above a certain point, the voltage output of a cell
drops dramatically.  The squiggly, vertical line indicates where
the maximum power (e.g. volts * amps) is obtained along the curve.
The upper graphs depict a typical curve with larger amounts
of light while the lower graphs are for smaller amounts of
impinging light.
This graph is from the Wikipedia article about MPPT - link
Click on the image for a slightly larger version.
"Constant Voltage" MPPT:

If you look at the current-versus-voltage curve of a typical solar panel as depicted in Figure 3 you'll note that there is a voltage at which the most power (volts * amps) can be produced (the squiggly vertical line) - a value typically around 70-80% of the open-circuit voltage, or somewhere in the area of 15-18 volts for a typical "12 volt" solar panel made these days.

Note:
Many "12 volt" panels currently being made are intended for use with MPPT controllers and have a bit of extra voltage "overhead" as compared to "12 volt" panels made many years ago before MPPT charging regimens were common.  What this means is that a modern "12 volt" panel may have an maximum power point voltage of 16-17 volts as opposed to 14-15 volts for an "older" panel made 10+ years ago.

One thing that you might notice is that, at least for higher amounts of light, the optimal voltage for maximum power for our hypothetical is about the same - approximately 0.45 volts per cell.  We can, therefore, design an MPPT circuit that is designed to cause the panel to operate only at that optimum voltage:  If the sunlight is reduced and the voltage starts to drop, the circuit will decrease the current it is pulling, but if the sunlight increases and the voltage starts to rise, it will increase the current to pull the voltage back down.


This method is simpler and cheaper to implement than the "Perturb and Observe" method because one does not need to monitor the current from the panel (e.g. it cares only about the voltage) and there does not need to be a small computer or some sort of logic to keep track of the previous adjustments.  For the Constant Voltage (e.g. "CV") method the circuit does only one thing:  Adjust the current up and down to keep the panel voltage constant.

As can be seen from Figure 3, the method of using "one voltage for all situations" is not optimal for all conditions as the voltage at which the most power can be obtained changes with the amount of light, which also changes with the temperature of the panel, age, shading, etc.  The end result of this rather simplistic method of optimization is that one ends up with somewhat lower efficiency overall - around 80% of the power that one might get with a well-performing P&O scheme according to some research. Ref. 1

This method can be optimized somewhat if the circuit is adjusted for maximum power output under "typical" conditions that one might encounter.  For example, if the CV voltage is adjusted when the panel is under (more or less) maximum sun on a typical day, it will produce power most efficiently when the solar power production is at its highest and making the greatest contribution to the task at hand - such as charging a battery.  In this case, it won't be optimized as well when the illumination is lower (e.g. morning or evening) but because the amount of energy available during these times will be lower anyway, a bit of extra loss from the lack of optimization at those times will be less significant than the same percentage of loss during peak production time.

Despite the lower efficiency, the Constant Voltage method is often found as a single-chip solution to implement low-cost MPPT, providing better performance than non-MPPT alternatives.

Actual implementation:

I was able to find an inexpensive (less than US$10, shipped) MPPT charge control board on EvilBay (called "5A MPPT Solar Panel Regulator Battery Charging") that was adjustable to allow its use with solar panels with open-circuit voltages ranging from 9 to 28 volts and its output being capable of being adjusted from 5 to about 17 volts.  This small board had built-in current regulation set to a maximum of 5 amps - more than adequate for the 18 watt panel that I would be using.

From the pictures on the EvilBay posting - and also once I had it in-hand - I could see that it used the Consonance CN3722 MPPT chip. Ref. 2  This chip performs Constant Voltage (CV) MPPT functions and provides a current-regulated output with the components on the EvilBay circuit board limiting the current to a maximum of 5 amps.  Additionally, this board, when used to charge a battery directly, may be adjusted, using onboard potentiometers, to be optimized for the solar panel's Maximum Power voltage (typically called "Vmp" in panels' specifications) and adjusted for the finish charge voltage for the battery itself, being suitable for many types of Lithium-Ion chemistries - including the "12 volt" LiFePO4 that I was going to use.
Figure 4:
The back side of the MPPT controller showing the heat sink and connections.
The heat sink is adequate for the ratings of this unit.  To save weight and bulk,
the unit was not put in a case, but rather the wires "zip tied" to the mounting
holes to prevent fatiguing of the wires - and to permit the wires themselves to
to offer a bit of protection to the top-side components.
Click on the image for a larger version.

To this end, my portable charging system consists of the solar panel, this MPPT controller and a LiFePO4 battery to provide a steady bus voltage compatible with 12 volt chargers and devices.  By including this "ballast" battery, the source voltage for all of the devices being charged is constant and as long as the average current being pulled from the battery is commensurate with the average solar charging current, it will "ride through" wide variations in solar illumination.  This method has the obvious advantage that a charge accumulated throughout the day can be used in the evening/night to charge those devices or even be used to top off batteries when one is hiking and the panel may not be deployed.

Tweaking the "Constant Voltage" MPPT board:

As noted, the EvilBay CN3722 board had two trimmer potentiometers:  One for setting the output voltage - which would be the "finish" charge voltage for the battery and another for setting the Constant Voltage MPPT point for the panel to be used.

Setting the output voltage is pretty easy:  After connecting it to a bench supply set for 4-6 volts above the desired voltage I connected a fairly light load to the output terminal and set it for the proper voltage.  For a "12 volt" LiFePO4 battery, this will be between 14.2 and 14.6 volts while the setting for a more conventional "12 volt" LiIon battery would be between 16.2-16.8 volts, depending on the chemistry and desired finish voltage. Ref. 3  Once this adjustment has been done I connected a fully-charged battery to the output along with a light load and power-cycled the MPPT controller and watched it as it stabilized, readjusting the voltage as necessary.

Setting the MPPT voltage is a bit tricker.  In this case, a partially discharged battery of the same type and voltage that will be ultimately used as was adjusted above is connected to the output of the MPPT controller in series with an ammeter on the output.  With the solar panel that is to be used connected and laid out in full sun, the "MPPT Voltage" potentiometer is adjusted for maximum current into the battery being charged.  Again, this step requires a partially-discharged battery so that it will take all of the charging current that is available from the panel.

Note that the above procedure also presumes that the solar panel is too small to produce enough power to cause the MPPT battery charger itself to go into current limiting - in which case, the current limit is that of the panel itself - which means that the maximum current that is seen at the charging terminal of the battery reflects the maximum power that can be pulled from the panel.  For example, with a panel producing 18 watts and charging a battery at 13.5 volts we could only ever expect to see about 1.33 amps flowing into the battery due to the inability of the panel to supply more power, but maximizing this current by adjusting the "MPPT" voltage control permits optimization for that particular solar panel.

If the panel is large enough to cause the MPPT controller to current-limit its charging current (around 5 amps for the MPPT controller that I used) then it may be that the panel is oversized slightly for the task - at least at midday, when there is peak sun.  In that case one would make the same adjustment in the morning or evening when the amount of light was low enough that the panel could not cause the charger to current-limit or simply block a section of the panel.

While this charging board would be able to connect directly to almost any rechargeable Lithium battery, it would be awkward try to adapt it for each type of battery that one might need to charge "on the trail" so I decided to carry with me a small "12 volt" LiFePO4 battery as well:  The solar panel and MPPT controller would charge that battery and then the various lightweight "12 volt" chargers for the different batteries to be charged would connect to it.

Its worth noting that MPPT power controllers use switching techniques to do the efficient conversion of voltage.  What this means is that if, attached to - or nearby - is a sensitive radio - particularly an  HF (shortwave) transceiver - the switching operation of the MPPT controller may cause interference unless the controller is enclosed in an RF-tight box with appropriate filtering on the input and output leads.  In practice I haven't found this to be an issue as any HF operation is usually done in the evening, at camp, as things are winding down and the sun isn't out, anyway, so the unit is not in service at that time.

Final comments

While the "ballast battery" method has an obvious weight and volume penalty, it has the advantage that if you need to charge a number of different devices, it is possible to find a very small and light 12 volt "car" charger for almost any type of battery that you can imagine.  The other advantage is that with a 12 volt battery that is being charged directly from the MPPT controller, it acts as "ballast", allowing the charging of this "main" battery opportunistically with the available light as well as permitting the charging of the other batteries at any time - including overnight!

The 18 watt panel weighs 519 grams (1.14 pounds), the MPPT charge controller with attached wires and connectors weighs 80 grams (0.18 pounds), a cable connecting the panel to the MPPT controller weights 60 grams (0.13 pounds) while the 6-7 amp-hour LiFePO4 battery pictured in Figure 1 . Ref. 4  weighs in at 861 grams (1.9 pounds).   The total weight of this power system is about 1520 grams (3.35 pounds) - which can be quite a bit to carry in a backpack, but considering that it can provide the power needs of a fairly large group and that this weight can be distributed amongst several people, if necessary, it is "tolerable" for all but those occasions where it is imperative that there is the utmost in weight savings.  For a "grab and go" kit that will be transported via a vehicle and carried only a short distance this amount weight is likely not much of an issue.


* * *
References:

1 - The article "Energy comparison of MPPT techniques for PV Systems" - link - describes several MPPT schemes, how they work, and provides comparison as to how they perform under various (simulated) conditions.

2 - Consonance Electric CN3722 Constant Voltage (CV) MPPT multichemistry battery charger/regulator - Datasheet link.

3 - Particularly true for LiIon cells, reducing the finish (e.g. cut off) voltage by 5-10%, while reducing the available cell capacity, can improve the cell's longevity.  What this means is that if the cut-off voltage of a typical modern LiIon cell, which is nominally 4.2 volts, is reduced to 4.0 volts, all other conditions being equal this can have the potential to double the useful working life.  While this lower cut off voltage may initially reduce the available capacity by as much as 25%, a cell consistently charged to the full 4.2 volts will probably lose this much capacity in a year or so, anyway whereas it will lose much less capacity than that at the lower voltage.  For additional information regarding increasing the longevity of LiIon cells see the Battery University web page "How to Prolong Lithium-based Batteries" - link and its reference sources.

4 - This LiFePO4 battery has been featured several times before - see these links:
  • Problems with LiFePO4 batteries - link
  • Follow-up:  LiFePO4 batteries revisited - equalization of cells - link


    [End]